Following configuration is for an Intel Xeon E5-2650 and Intel X520 NICs.
The Script will disable VMQ on iSCSI and enable and configure VMQ on converged VM and Fabric.
CPU distribution:
Script:
1 2 3 4 5 6 7 8 9 10 11 12 13 |
$adaptersd = "NIC5","NIC7","NIC9" #Disable VMQ on SAN NICs or Backup Disable-NetAdapterVmq -Name $adaptersd # Disable VMQ $adapterse = "NIC2-LACP-Fabric","NIC6-LACP-Fabric","NIC6-LACP-Fabric","NIC4-LACP-Fabric","NIC3-LACP-Fabric" #Enable VMQ on NICs with VMs or vNICs Enable-NetAdapterVmq -Name $adapterse # Enable VMQ #Set VMQ Settings Set-NetAdapterVmq -Name "NIC2-LACP-Fabric" -BaseProcessorNumber 2 -MaxProcessors 2 -MaxProcessorNumber 2 Set-NetAdapterVmq -Name "NIC3-LACP-VM" -BaseProcessorNumber 3 -MaxProcessors 4 -MaxProcessorNumber 10 Set-NetAdapterVmq -Name "NIC4-LACP-VM" -BaseProcessorNumber 15 -MaxProcessors 4 -MaxProcessorNumber 18 Set-NetAdapterVmq -Name "NIC6-LACP-Fabric" -BaseProcessorNumber 13 -MaxProcessors 2 -MaxProcessorNumber 14 Set-NetAdapterVmq -Name "NIC8-LACP-VM" -BaseProcessorNumber 19 -MaxProcessors 4 -MaxProcessorNumber 22 Get-NetAdapterVmq |